logo
infrastructure-engineering-and-civil

Turitea Actuators

Turitea Actuators

Contract Value: $570K
Palmerston North City

Contact our Infrastructure Engineering team today!

Reece Lloyd

Reece Lloyd

Infrastructure
Manager

E: reece.lloyd@maxtarr.co.nz
M: 027 455 5576

 

Mask Group 13

Nick Reid

Contracts
Manager

E: nick.reid@maxtarr.co.nz
M: 027 324 3114

Mask Group 21

Dylan Buckingham

Project
Engineer

Contact our Industrial team today!

Mask Group 9

Max Tarr

Executive Director

E: max.tarr@maxtarr.co.nz
M: 027 495 2468

Mask Group 8

Jonathan Hogg

Industrial Manager

E: Jonathan.hogg@maxtarr.co.nz
M: 027 444 2054

michael

Michael Hoggard

Project Manager

Contact our Commercial team today!

Dean Berendt

Dean Berendt

Commercial Manager

E: dean.b@maxtarr.co.nz
M: 022 639 3644

andrew

Andrew Tokley

Project Manager
Mask Group 18

Tony Boerboom

Fire & Security Supervisor

E: tony.boerboom@maxtarr.co.nz
M: 027 497 5697

20220804 110026
20220804 115556
20211217 133446
20220804 110617
20211217 132832
20211217 132728
20220804 110041
20220407 110433
20220407 1103480
20220407 103706
20220407 103609
20220407 103319
20220407 103130
20220407 103119
20211217 132930
20211217 133307
20211217 133248
20211217 133131
20211217 133050
20211217 133001
20211217 132719

This project involved replacing the existing, ageing electric actuators on the filter system and clarifiers at the Turitea WTP with new Kinetrol pneumatic actuators and custom designed and built pneumatic control system.

Supply and Installation of 58 new actuators including all airlines and control cables as follows:

  • 6 valves per filter, for 8 filters (48 valves)
  • 1 discharge valve for the backwash pumps
  • 8 inlet valves for the clarifiers
  • 1 Surge Tank Inlet valve
  • 3 local control panels including electrical control equipment, air reservoirs, solenoids, filters, and all pipework required as follows:
    • 1 to operate control valves locally/remotely and automatically for filters 1 to 4
    • 1 to operate control valves locally/remotely and automatically for filters 5 to 8
    • 1 to operate control valves locally/remotely and automatically for the clarifier inlet and drain valves as well as the surge tank valve and filter to stream valve

During this project there were significant variations due to the condition of existing equipment, valves and valve extensions that were identified during the works.

We worked with PNCC to undertake condition assessments as the works progressed and reported our findings and recommendations. This enabled PNCC to make informed decisions on replacing assets to ensure future reliable operation of their water treatment plant.

 